SEARCH RESULTS
Search this site
325 results found with an empty search
- SEWM009H3A-C -to- SEWM024H3A-C | Otecomega
High Wall On-Off Split Indoor Units 12 SEER SEWM-C Product Features Indoor Unit Features Anti-Corrosive Gold Fin Technology Wireless LCD Remote Control. Auto Setting for Cooling, Dehumidifying, Fan. Dry Anti-Mildew Design. Turbo Cooling Funtion with 4 Speed Fan. Auto Swing (Vertical). Easy Connect Flare Connections. Cleanable Cartridge Air Filter. 2 Meter Drain Hose. Self-Cleaning Gold Fin Technology Multi-Functional 3-1 Filter (Opt.) lonzer (Opt.) Wifi-Ready (Opt.) Submittal Form Catalog Technical Manual Service Manual
- SCHM009H3A-C -to- SCHM024H3A-C | Otecomega
High Wall On-Off Split Outdoor Units ---- SCHM-C Product Features Designed for Cooling up to 110F 0 ambient. Super Quiet Operation. Groved Copper Tubes. Rotary Compressor. Compressor Overload Protection. Over Current Protection. Discharge High Temperature Protection. Time Delay Protection. Low Voltage Startup. 3 Meter Cu/Cu Insulated Pipe Kit. 3.5 Meters Connecting Cable. Anti-Corrosive Gold Fin Technology Submittal Form Catalog Technical Manual Service Manual
- ERVD010A3N-F -to- ERVD060A3N-F | Otecomega
Energy Recovery Ventilators Energy Recovery Ventilators Direct Drive Three Speed ERVD-F ERVD / ERVB SERIES ENERGY RECOVERY VENTILATORS 220V/1/50Hz - 380V/3/50Hz Air Flow Volume Min~Max: 120~6,000 CFM (200~10,200 m3/h) Product Features Fresh Air Supply Ventilation. Low Noise Design. Simultaneous Exhaust & Supply Air. Free Cooling via Outside Fresh Air. Energy & Costs Savings. Advance Heat Exchange Core. Direct Drive 3 Speed on models up to 150. Single speed on models 180 & larger. Wired LCD Remote Control (Standard for 010-150). 7 Days programmable Controller (Optional) Optoelectronic Isolated Converter (Optional). Air Filtration and Purge Function. Compatible with VRF Systems. Easy Installation & Maintenance. Factory Tested. Submittal Form Catalog Technical Manual Service Manual
- VEHA070Q3A-G -to- VEHA096Q3A-G | Otecomega
Ducted FCU VRF Indoor Units High Static Ducted AHU VEHA-G 220V Series VEHA SERIES HIGH STATIC DUCTED VRF Indoor Unit Inverter Heat Pump 60 HZ Cooling Capacity Min~Max: 68,240~95,540 Btuh {20.0~ 28.0 kW) Heating Capacity Min~Max: 75,070 ~ 105,090 Btuh {22.0~30.8 kW) Product Features Full DC Inverter Technologies. Built in Drain Pump Available for VEHP Series. Auto Restart. Excellent Comfort for Commercial & Industrial Solutions. Self Diagnosis Function. Factory Tested. High Static Pressure Design. Easy Maintenance. Wired LCD Remote Control (Standard). Wireless LCD Remote Control (Optional). Deluxe Wired Controller (Optional). Centralized controller (Optional). Remote monitoring software (Optional). Anti-Freezing Protection. Fan Motor Overload Protection. Temperature Sensor Malfunction Submittal Form Catalog Technical Manual Service Manual
- IELP618K2A-MP624K-MP636K-HP660K-G | Otecomega
Ducted FCU Indoor Units Up to 16 SEER IELP (MP,HP)-G Product Features Up to 16 SEER Cooling Cooling and Heating System Auto Restart. Self-Diagnosis. R410A Refrigerant. Ideal for Small Commercial & Industrial Aplications. AC Fan Motor Flexible Installation Air Return Easy Maintenance for Filter Direct access for Electronic Control Box Low Static, Medium Static, High Static Selection Self-Diagnostic Multi-Protection Auto-Restart Quiet Centrifugal Blower Wired Controller (Standard) Remote Controler (Optional) 24V Thermostat (Optional) Submittal Form Catalog Technical Manual Service Manual
- VEMP024Q0A-G -to- VEMP060Q0A-G | Otecomega
Ducted FCU VRF Indoor Units Medium Static VEMP-G 220V Series VE (LP-MP) SERIES STATIC DUCTED VRF Indoor Unit 3D Inverter Heat Pump Cooling Capacity Min~Max: 5,100 ~ 54,600 BTU/h (1.5 ~ 16.0 kW) Heating Capacity Min~Max: 6,100 ~ 61,400 BTU/h (1.8 ~ 18.0 kW) Product Features Third Generation Indoor Unit System Full DC Inverter Technologies Built in Drain Pump. Excellent Comfort for Rooms & Compact Solutions. Self-Diagnosis Function. Factory Tested. Medium Static Pressure Design. Easy Maintenance. Heat Exchanger Self-Cleaning. Small Installation Space. Wired LCD Remote Control (Standard). Wireless LCD Remote Control (Optional). Deluxe Wired Controller with Weekly Timer (Optional). Centralized controller (Optional). Smart Zone Controller (Optional). Remote monitoring software (Optional). Anti-Freezing Protection. Fan Motor Overload Protection. Temperature Sensor Malfunction. Water Overflow Protection. Wider Capacity Range. Ultra-Thin Fuselage. Efficiency Filter Screen. Constant Airflow Technology. Intelligent Drainage Device. Submittal Form Catalog Technical Manual Service Manual
- APRI636J2A-G -to- APRI860J0A-G | Otecomega
Air Cooled Package Units 16-18 SEER APRI-G Product Features Up To 5 Tons in Cooling and Heating Mode. 16 and 18 SEER in Cooling DC Inverter Design DC Inverter Motor GMCC and Mitsubishi Compressor High Efficiency Fan Blade Excellent Grid Adaptability Multiple Protection Design Refrigerant Cooling Protection Easy Maintenance and Installation Automatic Adjustment of Throttling Axial Fan Design of Outdoor Fan Cooling Operation from 17°C to 48°C Heating Operation from -15°C to 30°C 24V Low Voltage Control (Standard) Submittal Form Catalog Technical Manual Service Manual
- BECM006N0A-D / BECM022N0A-D | Otecomega
Four Way Cassette Indoor Units Ultima BECM-D Series C Generation BECM Ultima SERIES 220-240V/1/50-60 Hz (Full DC) MINI CASSETTE VRF Indoor Unit Inverter Heat Pump 50-60 HZ Cooling Capacity Min ~ Max: 5,100 ~ 21,500 BTU/h (1.5 ~ 6.3 kW) Heating Capacity Min ~ Max: 6,100 ~ 24,200 BTU/h (1.8 ~ 7.1 kW) Product Features Built-in Electronic Expansion Valve. Built-in Drain Pump. Auto Restart. Excellent Comfort for Commercial & Industrial Solutions. Self Diagnosis Function. Factory Tested. Automatic Defrosting. Low oltage Start Up. Wireless LCD Remote Control {Standard). Wired LCD Remote Control (Optional). Deluxe Wired Controller with Weekly Timer (Optional). Centralized controller (Optional). Remote monitoring software (Optional). 8 Direction Airflow. Ultra-Low Noise Operation. DC Inerter Motor. Compact Design. Intelligent Drainage Deice. Submittal Form Catalog Technical Manual Service Manual
- WEFC002C2W-R -to- WEFC012C2W-R | Otecomega
Floor/Ceiling Chilled Water Indoor Units Water Fan Coil WEFC-R WEFC SERIES Floor Ceiling Fan Coil Units 235-1,200 CFM (400-2,040 m3/h) Cooling Capacity: 10,000-33,100 Btuh (2.9-9.7 kW) Heating Capacity: 18,300-54,250 Btuh (5.4-15.9 kW) Product Features Cooling & Heating. Auto Clean Function. Inner Groove Cooper Tubes . Compact Design . Multi Fan with 3 Speeds. Wireless Remote Controller. Easy Connect Threaded Brass Connections. Self Diagnosis . Whisper Quiet Design. Anti-Cold Function . Washable Filter. Microcomputer Control. Product Features (Optional) Wired Remote Controller (WCA-CC308) . 3 Way Electronic Valve, 3/4 (WECA-3V340A) . Copper Fins . Submittal Form Catalog Technical Manual Service Manual
- VAECD-D120VB | Otecomega
Wired Controller Controller VAECD-D120VB Our advanced Wired Controller for VRF Indoor Units is a centralized control hub for up to 16 indoor units, enabling uniform environmental settings. It supports pairing with another controller, with operation based on the latest instructions received. Enhanced with bi-directional communication, it allows for real-time querying of system parameters. Users can easily adjust settings like static pressure, cold draft prevention, and temperature compensation. Its weekly schedule timer enables the creation of personalized schedules with distinct modes, temperature settings, and fan speeds. Synchronized display across controllers ensures consistent information updates. Focused on user comfort, energy efficiency, and seamless control, this Wired Controller revolutionizes your indoor living experience. Submittal Form Catalog Technical Manual Service Manual









